📦 Free Express Shipping on orders over $150 — Australia-wide
💎 Save up to 22%
Sale!

CJC-1295 – 5mg | Research Peptide Australia | Aventris

Original price was: $209.00.Current price is: $152.90. inc. GST


✓ Verified BVR 99.55% Purity No Fillers Free Reship Guarantee
High-purity CJC-1295 (No DAC) / Modified GRF 1-29 (99.55% HPLC, 95.74% mass balance). Each vial includes a Batch Verification Report featuring HPLC data, mass spectrometry confirmation, and peptide content analysis, plus a batch-specific QR code for instant documentation access. Australian supplier with fast domestic shipping. If your order doesn’t arrive, we reship free. Research use only.

SKU: AV-R110 Category:

Analytical Reference Standard

CJC-1295 (No DAC)

High-purity Modified GRF (1-29) analytical reference material – 29-amino acid synthetic peptide

99.55%
HPLC Purity
BVR verified
84.87%
Peptide Content
BVR verified
1.45%
Water Content
Excellent stability
95.74%
Mass Balance
Verified
Batch Verification Report (BVR)
Complete Analytical Data
Australian Laboratory Supply
29-Amino Acid Peptide

Product Overview

Aventris Labs supplies research-grade CJC-1295 (No DAC), also known as Modified GRF (1-29) or Mod GRF 1-29, as an analytical reference standard. This 29-amino acid synthetic peptide is manufactured using solid-phase peptide synthesis (SPPS) with comprehensive analytical verification.

Primary applications: Reference standard for method development, analytical validation, peptide characterisation studies, and comparative quality control.

Documentation Included

  • Batch Verification Report (BVR) – Complete batch-specific analytical data
  • HPLC chromatography – 99.55% purity with retention time data
  • Mass spectrometry (ESI-MS) – Molecular weight confirmation (3367.97 Da)
  • Peptide content assay – 84.87% by nitrogen analysis
  • Mass balance – 95.74% verified
  • Karl Fischer water content – 1.45% (excellent stability)
  • Acetate content – 9.42% (well within specification)
  • Batch verification portal – QR code and online lookup system

Analytical Data (Batch Verification Report)

The following data represents typical batch results. Your batch-specific values are available in your Batch Verification Report (BVR) via the verification portal.

Parameter Result Specification Status
Purity (HPLC) 99.55% ≥98.0% PASS
Peptide Content (N%) 84.87% ≥80.0% PASS
Molecular Weight (ESI-MS) 3367.97 Da Conforms to structure PASS
Mass Balance 95.74% 95.0-105.0% PASS
Water Content (Karl Fischer) 1.45% ≤10.0% PASS
Acetate Content 9.42% <17.0% PASS
Appearance White powder White powder PASS

Peptide Information

Synonyms Modified GRF (1-29), Mod GRF 1-29, Tetrasubstituted GRF (1-29)
Molecular Weight 3367.97 Da
Sequence Length 29 amino acids
Source Synthetic peptide
Synthesis Method Solid-phase peptide synthesis (SPPS)

Ordering Information

📦

Package Contents

CJC-1295 (No DAC) lyophilized powder in sealed glass vial with batch-specific labeling and QR verification code.

📄

Batch Verification Report

Complete BVR with all analytical data accessible via QR code scan, email link, or online verification portal at aventrislabs.com/verify.

🚚

Australian Shipping

Australian domestic express shipping. Orders dispatched within 1-2 business days.

💰

Tier Pricing Available

Volume discounts for research facilities and repeat orders. Contact for institutional pricing and bulk quantities.

Quality & Verification

Batch Verification Report (BVR)

Every batch includes comprehensive analytical documentation through Aventris Labs’ verification system, presenting all manufacturer analytical data in a standardized format.

🔬

Complete Analytical Data

HPLC purity, peptide content, mass spectrometry, water content, acetate content, and mass balance data included in every BVR.

🔗

Online Verification Portal

Instant batch verification via QR code or manual lookup. Access your batch-specific BVR anytime at aventrislabs.com/verify.

🇦🇺

Australian Laboratory Supply

Aventris Labs is an Australian supplier providing research-grade peptide reference materials to universities and biotech laboratories.

Complete Specifications

Product Name CJC-1295 (No DAC)
Synonyms Modified GRF (1-29), Mod GRF 1-29
Description Modified 29-amino acid synthetic peptide analogue
Molecular Weight 3367.97 Da (ESI-MS verified)
Sequence Length 29 amino acids
Physical Form White to off-white lyophilized powder
Purity (HPLC) 99.55% (typical, ≥98% specification)
Peptide Content 84.87% (typical, ≥80% specification)
Mass Balance 95.74% (typical, 95-105% specification)
Water Content 1.45% (typical, ≤10% specification)
Acetate Content 9.42% (typical, <17% specification)
Storage Conditions Cool, dry place protected from light; -20°C for extended storage
Shelf Life 24 months when stored properly (retest date on BVR)
Intended Use Analytical Reference Standard / Research Use Only
Regulatory Status Not for human or veterinary use; laboratory research only

Frequently Asked Questions

Product Specifications

What is CJC-1295 (No DAC)?

CJC-1295 (No DAC), also known as Modified GRF (1-29) or Mod GRF 1-29, is a 29-amino acid synthetic peptide. The “No DAC” designation indicates this variant does not contain the Drug Affinity Complex structural modification. This product is supplied strictly as an analytical reference standard for laboratory research.

What is the difference between CJC-1295 with DAC and without DAC?

CJC-1295 (No DAC), also called Mod GRF 1-29, is the base 29-amino acid peptide without additional structural modification. CJC-1295 with DAC includes a lysine-linked maleimidopropionic acid moiety, resulting in a higher molecular weight and distinct analytical profile. Both are available from Aventris as separate analytical reference standards.

What analytical data is provided?

Each batch includes a comprehensive Batch Verification Report (BVR) containing all manufacturer analytical data: HPLC purity (99.55%), peptide content (84.87%), ESI-MS molecular weight confirmation (3367.97 Da), mass balance (95.74%), Karl Fischer water content (1.45%), and acetate content (9.42%). Access via QR code or online verification portal.

How do I verify my batch?

Three methods: (1) Scan QR code on product label, (2) Click verification link in order confirmation email, (3) Visit aventrislabs.com/verify and enter batch ID. All provide instant access to your batch-specific Batch Verification Report with complete analytical data.

What is the shelf life?

Typically 24 months when stored in sealed vial at -20°C or below, protected from light and moisture. Specific retest date listed on Batch Verification Report.

Regulatory & Compliance

What is the regulatory status of CJC-1295 in Australia?

CJC-1295 (No DAC) is supplied for research use only. It is NOT approved for human consumption, therapeutic use, veterinary applications, or diagnostic procedures. Purchasers are responsible for ensuring compliance with all applicable regulations.

Does Aventris provide research protocols or application guidance?

No. Aventris supplies analytical reference materials only. We do not provide reconstitution protocols, application methods, dosing information, or research design guidance. Researchers must develop protocols based on scientific literature and appropriate oversight.

Regulatory Disclaimer – Analytical Reference Material

⚠️

CJC-1295 (No DAC) is supplied as an analytical reference standard for research use only.

NOT for:

  • Human consumption, administration, or therapeutic use
  • Veterinary or animal health applications
  • Diagnostic procedures
  • Clinical trials or medical research involving human subjects (without appropriate approvals)
  • Food, cosmetic, or dietary supplement applications
  • Personal or consumer use of any kind

Purchaser Responsibilities:

  • Verify compliance with all applicable federal, state, and local regulations
  • Maintain proper laboratory safety and handling procedures
  • Ensure appropriate storage, documentation, and chain of custody
  • Use only for legitimate analytical/research purposes as intended

Aventris Labs Does NOT Provide:

  • Medical, therapeutic, or health-related advice
  • Dosing recommendations or administration protocols
  • Reconstitution instructions or methods
  • Research design or experimental methodologies

Order CJC-1295 (No DAC) Analytical Reference Material

Add CJC-1295 (No DAC) to your cart. Every order includes complete Batch Verification Report (BVR) with all analytical data, batch verification portal access, and Australian domestic express shipping.

99.55% HPLC Purity
Complete BVR Included
Mod GRF 1-29
Batch Verification Portal


Scroll to Top