CJC-1295 (No DAC) + Ipamorelin – 10mg
Two-component multi-peptide blend — 5mg CJC-1295 (No DAC) and 5mg Ipamorelin in a single pre-mixed lyophilized vial. Two individually verified research peptides, one convenient vial.
Total Content
2-peptide blend
Min. Component Purity
Both components verified
Verification Reports
Per-component data
Pure Peptide Only
Filler-free formulation
Pre-Mixed Single Vial
Australian Laboratory Supply
Filler-Free Guarantee
Blend Composition
Product Overview
Aventris Labs supplies the CJC-1295 (No DAC) + Ipamorelin Blend as a pre-mixed, two-component research formulation combining CJC-1295 (No DAC) and Ipamorelin in a single lyophilized vial. Each component is sourced from verified manufacturers and independently verified through the Aventris Batch Verification Report (BVR) system.
This blend brings together two structurally distinct peptides in a single vial for multi-component analytical workflows. CJC-1295 (No DAC), also known as Mod GRF 1-29, is a synthetic 29-amino acid peptide analogue (MW 3367.97 Da). Ipamorelin is a synthetic pentapeptide growth hormone secretagogue (CAS 170851-70-4, MW 712.03 Da).
Why buy the blend? The CJC + IPA Blend delivers two independently verified peptides in a single pre-mixed vial — eliminating the need to source, weigh, and combine components separately. One vial, two BVRs, zero guesswork.
Documentation Included
- 2× Batch Verification Reports (BVRs) – Individual component analytical data for CJC-1295 (No DAC) and Ipamorelin
- HPLC chromatography – Purity confirmed for each component (99.55%, 99.45%)
- Mass spectrometry (ESI-MS) – Molecular weight confirmation for both peptides
- Peptide content assay – Per-component content verified
- Water content (Karl Fischer) – Per-component moisture data
- Acetate content results – Per-component counterion data
- Mass balance analysis – Both components within specification
- Batch verification portal – QR code and online lookup for both BVRs
Analytical Data (Batch Verification Reports)
Each component is independently verified. Your batch-specific values are available in your individual Batch Verification Reports (BVRs) via the verification portal.
Component 1: CJC-1295 No DAC / Mod GRF 1-29 (5mg)
| Parameter | Result | Specification | Status |
|---|---|---|---|
| Purity (HPLC) | 99.55% | ≥98.0% | PASS |
| Peptide Content (N%) | 84.87% | ≥80.0% | PASS |
| Molecular Weight (ESI-MS) | 3367.97 Da | Conforms | PASS |
| Water Content (Karl Fischer) | 1.45% | ≤10.0% | PASS |
| Acetate Content (HPLC) | 9.42% | <17.0% | PASS |
| Mass Balance | 95.74% | 95.0–105.0% | PASS |
Component 2: Ipamorelin (5mg)
| Parameter | Result | Specification | Status |
|---|---|---|---|
| Purity (HPLC) | 99.45% | ≥98.0% | PASS |
| Peptide Content (N%) | 73.73% | ≥70.0% | PASS |
| Molecular Weight (ESI-MS) | 712.03 Da | Conforms | PASS |
| Water Content (Karl Fischer) | 2.87% | ≤10.0% | PASS |
| Acetate Content (HPLC) | 19.02% | <20.0% | PASS |
| Mass Balance | 95.62% | 95.0–105.0% | PASS |
Peptide Sequences
CJC-1295 No DAC / Mod GRF 1-29 (29 AA): Tyr-D-Ala-Asp-Ala-Ile-Phe-Thr-Gln-Ser-Tyr-Arg-Lys-Val-Leu-Ala-Gln-Leu-Ser-Ala-Arg-Lys-Leu-Leu-Gln-Asp-Ile-Leu-Ser-Arg-NH₂
Ipamorelin (5 AA): Aib-His-D-2-Nal-D-Phe-Lys-NH₂
Ordering Information
Package Contents
10mg CJC + IPA Blend (5mg CJC-1295 No DAC + 5mg Ipamorelin) as pre-mixed lyophilized powder in a single sealed glass vial with batch-specific labeling and QR verification code.
2× Batch Verification Reports
Individual BVRs for each component (CJC-1295 No DAC and Ipamorelin) with full analytical data. Both accessible via a single QR code scan or online at aventrislabs.com/verify.
Australian Express Shipping
Fast domestic express shipping Australia-wide. If your order doesn’t arrive, we reship free — no questions asked.
Pre-Mixed Convenience
Both components professionally combined in a single lyophilized vial — no weighing, measuring, or mixing required. Ready for your research workflow.
Quality & Verification
Per-Component BVRs
Every CJC + IPA Blend includes two individual Batch Verification Reports — one for each component peptide — presenting all manufacturer analytical data in a standardised format.
Complete Analytical Data
HPLC purity, peptide content assay, mass spectrometry, water content, acetate content, and mass balance data included across both BVRs.
Online Verification Portal
Single QR code links to both component BVRs. Access your batch-specific data anytime at aventrislabs.com/verify.
Australian Laboratory Supply
Aventris Labs is an Australian supplier providing research-grade peptide reference materials to universities and biotech laboratories nationwide.
Complete Specifications
| Product Name | CJC-1295 (No DAC) + Ipamorelin Blend |
| Description | Two-component multi-peptide research blend |
| Composition | 5mg CJC-1295 (No DAC) + 5mg Ipamorelin = 10mg total |
| Format | Single vial, pre-mixed lyophilized powder |
| Physical Form | White lyophilized powder |
| CJC-1295 (No DAC) Molecular Weight | 3367.97 Da |
| Ipamorelin Molecular Formula | C₃₈H₄₉N₉O₅ — 712.03 Da — CAS 170851-70-4 |
| CJC-1295 (No DAC) Purity | 99.55% HPLC |
| Ipamorelin Purity | 99.45% HPLC |
| Storage Conditions | Cool, dry place protected from light; -20°C for extended storage |
| Shelf Life | 24 months when stored properly (retest dates on individual BVRs) |
| Intended Use | Analytical Reference Standard / Research Use Only |
| Regulatory Status | Not for human or veterinary use; laboratory research only |
Frequently Asked Questions
About the Blend
What is the CJC + IPA Blend?
The CJC + IPA Blend is a pre-mixed, two-component research formulation containing 5mg CJC-1295 (No DAC) — also known as Mod GRF 1-29 — and 5mg Ipamorelin in a single lyophilized vial. Both peptides are independently verified with individual Batch Verification Reports.
Is the blend pre-mixed or a multi-vial kit?
Pre-mixed. Both components are combined into a single lyophilized vial — no need to weigh, measure, or combine anything. One vial contains 5mg CJC-1295 (No DAC) and 5mg Ipamorelin.
What does “No DAC” mean?
CJC-1295 (No DAC) refers to the version of the peptide without the Drug Affinity Complex (DAC) modification. This is also commonly referred to as Mod GRF 1-29 or Modified GRF(1-29). It is a 29-amino acid peptide with a molecular weight of 3367.97 Da.
Quality & Verification
How are the components verified if it’s a blend?
Each component is independently sourced and verified before blending. You receive two individual Batch Verification Reports (BVRs) — one for CJC-1295 (No DAC) and one for Ipamorelin — each containing the full manufacturer analytical data for that component. Both BVRs are accessible through a single QR code on the vial label.
How do I verify my batch?
Three methods: (1) Scan QR code on product label, (2) Click verification link in order confirmation email, (3) Visit aventrislabs.com/verify and enter batch ID. All provide instant access to both component Batch Verification Reports.
What analytical data is provided?
Two full BVRs covering: CJC-1295 (No DAC) — HPLC purity (99.55%), peptide content (84.87%), ESI-MS (3367.97 Da), water content, acetate content, mass balance. Ipamorelin — HPLC purity (99.45%), peptide content (73.73%), ESI-MS (712.03 Da), water content, acetate content, mass balance.
Regulatory & Compliance
What is the regulatory status of this blend in Australia?
The CJC + IPA Blend is supplied for research use only. It is NOT approved for human consumption, therapeutic use, veterinary applications, or diagnostic procedures. Purchasers are responsible for ensuring compliance with all applicable regulations.
Does Aventris provide research protocols or application guidance?
No. Aventris supplies analytical reference materials only. We do not provide reconstitution protocols, application methods, dosing information, or research design guidance. Researchers must develop protocols based on scientific literature and appropriate oversight. For technical science questions, resources such as Grok AI can assist with research-level inquiries.
Regulatory Disclaimer – Analytical Reference Material
The CJC-1295 (No DAC) + Ipamorelin Blend is supplied as an analytical reference standard for research use only.
NOT for:
- Human consumption, administration, or therapeutic use
- Veterinary or animal health applications
- Diagnostic procedures
- Clinical trials or medical research involving human subjects (without appropriate approvals)
- Food, cosmetic, or dietary supplement applications
- Personal or consumer use of any kind
Purchaser Responsibilities:
- Verify compliance with all applicable federal, state, and local regulations
- Maintain proper laboratory safety and handling procedures
- Ensure appropriate storage, documentation, and chain of custody
- Use only for legitimate analytical/research purposes as intended
Aventris Labs Does NOT Provide:
- Medical, therapeutic, or health-related advice
- Dosing recommendations or administration protocols
- Reconstitution instructions or methods
- Research design or experimental methodologies
Order CJC-1295 (No DAC) + Ipamorelin – 10mg Blend
Add the CJC + IPA Blend to your cart. Every order includes two Batch Verification Reports, batch verification portal access, filler-free guarantee, and Australian domestic express shipping with free reship guarantee.





