πŸ“¦ Free Express Shipping on orders over $150 β€” Australia-wide
β€’ πŸ’Ž Save up to 22% β†’
Aventris Labs

Batch Verification Report

Batch verification and analytical summary for CJC-1295 with DAC.

Batch Code: P251212-A003
BVR ID: CJC1295DACP251212-A003-BVR-20260128
Revision: 1.0
Research Use Only
Product
CJC-1295 with DAC (Drug Affinity Complex)
Synonyms
CJC-1295 DAC, DAC:GRF
Intended use
Laboratory research and analytical reference applications only.
Batch & dates
Batch: P251212-A003
Date of analysis: 19 Dec 2025
Recommended retest date: 18 Dec 2027
Form & specifications
Form: Lyophilised peptide powder
Molecular weight: 3647.28 Da
Storage
Store in a cool, dry place away from light. Follow Aventris storage guidance on the product label.

Analytical Results

The following analytical data was obtained from manufacturer testing of batch P251212-A003. Aventris has independently verified this data against our quality specifications. This Batch Verification Report summarises our review findings.

Test Method Specification Result
Appearance Visual White powder Conforms
Identity MS (ESI) Conforms to structure Conforms (3647.28 Da)
Purity HPLC ≥ 98.0% 98.55%
Peptide content Peptide content (N%) ≥ 70.0% 76.55%
Water content Karl Fischer ≤ 10.0% 1.77%
TFA content HPLC 18 – 24% 17.88%*
Mass balance Calculated 95.0 – 105.0% 96.20%
* Note: TFA content (17.88%) is marginally below the manufacturer's stated specification of 18-24%. This is a counter-ion variance and does not affect peptide purity or identity. The batch has been accepted for distribution following Aventris QA review. All other parameters conform to specification.

Storage & Handling

Storage Conditions:

  • Store at -20Β°C or below in original sealed vial
  • Protect from light and moisture
  • Do not freeze-thaw repeatedly once reconstituted
  • Recommended shelf life: 24 months when stored properly

General Laboratory Handling:

  • Handle using standard laboratory safety practices
  • Wear appropriate personal protective equipment (gloves, lab coat, safety glasses)
  • Use in well-ventilated area or fume hood
  • Avoid inhalation, ingestion, or skin/eye contact
  • Wash hands thoroughly after handling

Reconstitution:
Reconstitution methods, diluents, and working concentrations must be determined by qualified researchers according to their specific experimental protocols and institutional guidelines. Aventris does not provide reconstitution instructions.

Additional Documentation:
For questions about this batch or to request additional information, contact [email protected]

Note: Any deviations from the above specification, if present, will be explicitly noted. In the absence of such notes, all parameters conform to the stated limits.

Scroll to Top