Batch Verification Report
Batch verification and analytical summary for Retatrutide.
Manufacture date: 01 Sep 2025
Recommended retest date: 31 Aug 2027
Amount: As specified on Aventris product label
Analytical Results
The following analytical data was obtained from manufacturer testing of batch P250712-L013. Aventris has independently verified this data against our quality specifications. This Batch Verification Report summarises our review findings.
| Test | Method | Specification | Result |
|---|---|---|---|
| Appearance | Visual | White powder | Conforms |
| Solubility (water) | Visual / solubility check | ≥ 30 mg/mL | Conforms |
| Identity | MS (ESI) | Mw 4731.33 Β± 1.0 | 4731.40 |
| Purity | HPLC | ≥ 98.0% | 99.37% |
| Peptide content | Peptide content (N%) | ≥ 85.0% | 92.19% |
| Water content | Karl Fischer | ≤ 10.0% | 3.58% |
| pH (5 mg/mL) | pH meter | 6.0 β 8.0 | 7.25 |
| Acetate content | HPLC | ≤ 15.0% | Not detected |
| TFA content | HPLC | ≤ 0.5% | Not detected |
| Sodium salt | Calculated / ion analysis | < 5.0% | 1.79% |
| Residual solvents β Acetonitrile | GC | NMT 410 ppm | Not detected |
| Residual solvents β Methanol | GC | NMT 3000 ppm | Not detected |
| Residual solvents β Methylene chloride | GC | NMT 600 ppm | Not detected |
| Residual solvents β N,N-Dimethylformamide | GC | NMT 880 ppm | Not detected |
| Residual solvents β Isopropyl ether | GC | NMT 5000 ppm | Not detected |
| Bacterial endotoxins | Pharmacopeial method | < 10 EU/mg | Conforms |
| Total aerobic microbial count | Plate count | ≤ 1000 cfu/g | Conforms |
| Total yeast & mold count | Plate count | ≤ 200 cfu/g | Conforms |
| Assay (HPLC) | HPLC | 95.0 β 105.0% (anhydrous, salt-free basis) | 99.45% |
Storage & Handling
Storage Conditions:
- Store at -20Β°C or below in original sealed vial
- Protect from light and moisture
- Do not freeze-thaw repeatedly once reconstituted
- Recommended shelf life: 24 months when stored properly
General Laboratory Handling:
- Handle using standard laboratory safety practices
- Wear appropriate personal protective equipment (gloves, lab coat, safety glasses)
- Use in well-ventilated area or fume hood
- Avoid inhalation, ingestion, or skin/eye contact
- Wash hands thoroughly after handling
Reconstitution:
Reconstitution methods, diluents, and working concentrations must be determined by qualified researchers
according to their specific experimental protocols and institutional guidelines. Aventris does not provide
reconstitution instructions.
Additional Documentation:
For questions about this batch or to request additional information, contact
[email protected]
Note: Any deviations from the above specification, if present, will be explicitly noted. In the absence of such notes, all parameters conform to the stated limits.